Template:StimulusTaskParams
WindowBackgroundColor
The window's background color, given as an RGB value. For convenience, RGB values may be entered in hexadecimal notation, e.g. 0xff0000 for red.
PreRunDuration
The duration of the pause preceding the first sequence. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.
PostRunDuration
Duration of the pause following last sequence. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.
PreSequenceDuration
Duration of the pause preceding sequences (or sets of intensifications). Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.
PostSequenceDuration
Duration of the pause following sequences (or sets of intensifications). Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.
StimulusDuration
For visual stimuli, the duration of stimulus presentation. For auditory stimuli, the maximum duration. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar.
ISIMinDuration, ISIMaxDuration
Minimum and maximum duration of an inter-stimulus interval. Actual inter-stimulus intervals vary randomly between these values, with uniform probability for all intermediate values. Given in sample blocks, or in time units when immediately followed with 's', 'ms', or similar. Note that temporal resolution is limited to a single data block.
InterpretMode
An enumerated value selecting on-line classification of evoked responses:
- 0: no target is announced "attended", and no classification is performed;
- 1: online or free mode: Classification is performed, but no target is announced;
- 2: copy mode: pre-defined targets are announced, classification is performed.
DisplayResults
Switches result display of copy/free spelling on or off.